Cameron Instruments Inc. Pressure, Temperature, Flow
Instrumentation for Calibration, Measurement and Test
HOME SUPPORT YOU CAN COUNT ON
PIE - Practical Instrument Electronics, Inc.
.

PIE Process Calibrators: Loop, RTD & T/C Calibrators
Featured Products:
RTD Simulator & Calibrator
512 RTD Calibrator

Thermocouple Simulator & Calibrator
522 Thermocouple Calibrator

T/C & RTD Dual Calibrator
525 T/C & RTD Dual Calibrator

4-20 mA Loop Calibrator
532 Loop Calibrator with Loop Diagnostic

Frequency Calibrator
541 Frequency Calibrator with Totalizer

Cameron Instruments can configure a "calibration system or calibration kit" for your specific requirements, call us for more info. 1-888-863-8010


RTD Simulator & Calibrator

PIE 512 RTD Calibrator
PIE 512 RTD Calibrator
Need More information?
Download 512 RTD Calibrator Brochure PDF
Download PDF
>Visit PIE's website

  
Back to top - click here
The Practical Instrument Electronics Model 512 RTD Calibrator provides direct temperature calibration to all types of instruments such as transmitters, recorders, controllers, alarms, data acquisition, and computer systems.  Also, the Model 512 reads RTD outputs and displays in temperature.  It is compatible with pulsed systems and transmitters (like the Rosemount 3144.) 2, 3, or 4 wire connections to RTD sensors are detected automatically.  The model 512 is a superior replacement for decade boxes, eliminating the need for lugging around large equipment and the possibility of misreading RTD tables.

Select from 7 RTD types to source/read in °C or °F with 0.1 ° resolution. Or, select Ohms; for direct resistance source/read capability. Using the EZ-Check™ Switch you can recall minimum and maximum readings.  Store/Clear memory with a press of the EZ-Dial™ Knob.

The Practical Instrument Electronics Model 512 offers the highest performance and functions in its class by exceeding the accuracy and functions of many higher priced RTD calibrators.  It is a low cost solution for checkout and calibration of all RTD instruments in the field, shop or control room.
Features
  • Simulate/Read RTD sensors
  • Several Manufacturers' RTD curves available
  • Accurate to ± 0.25°C (± 0.5°F) with 0.1° Resolution
  • Guaranteed to work with all Pulsed Instruments
  • EZ-Dial Knob
  • EZ-Check Switch
  • Uses a standard 9V Alkaline Battery
  • Lightweight, Rugged and Reliable


Thermocouple Simulator & Calibrator

PIE 522 Thermocouple Calibrator
PIE 522 Thermocouple Calibrator
Need More information?
Download 522 Thermocouple Calibrator Brochure PDF
Download PDF
>Visit PIE's website
  
Back to top - click here
The Practical Instrument Electronics Model 522 is a complete source/read Thermocouple Calibrator providing direct temperature input to all types of instruments such as transmitters, recorders, controllers, alarms, data acquisition, and computer systems.  The Model 522 also reads thermocouple outputs and displays temperature, eliminating the need for cumbersome books of conversion tables.

The Model 522 is equipped with a miniature T/C connector and slotted screws to connect to common thermocouple equipment or bare extension wire.  Select from 8 T/C types to source/read in °C or °F with 0.1° resolution or, select mV for direct millivolt source/read capability.  The Model 522 is internally cold-junction compensated for accuracy in any operating environment.

Use the EZ-Check™ Switch to quickly switch between three stored temperature/mV outputs.  It's easy to customize these values to your application.

The Practical Instrument Electronics Model 522 offers the highest performance and functions in its class by exceeding the accuracy and functions of many higher priced thermocouple calibrators.
Features
  • Direct Temperature Input/Output
  • 8 Standard T/C types available
  • Accurate to ±0.2°C (±0.4°F) with 0.1° resolution
  • EZ-Dial™ Knob
  • EZ-Check™ Switch
  • Uses a standard 9V Alkaline Battery


T/C & RTD Dual Calibrator

PIE 525 T/C & RTD Dual Calibrator with Auto Stepping
PIE 525 T/C & RTD Dual Calibrator with Auto Stepping
Need More information?
Download 525 T/C & RTD Dual Calibrator Brochure PDF
Download PDF
>Visit PIE's website

  
Back to top - click here
The Practical Instrument Electronics Model 525 T/C & RTD calibrator provides direct temperature calibration to all types of instruments such as transmitters, recorders, controllers, alarms, data acquisition and computer systems.  Also, the Model 525 reads RTD & T/C outputs and displays temperature.  It is compatible with pulsed systems and transmitters 2, 3, or 4 wire connections are detected automatically.  The Model 525 is a superior replacement for decade boxes, and eliminates the need for lugging around large equipment and the possibility of misreading RTD tables.
Features
  • Direct replacement to high resolution decade boxes
  • Selectable resolution 0.01º or 0.001º
  • "Widest" Compatibility with field devices available
  • In RTD mode automatic detection of 2, 3 or 4 wire connections
  • Guaranteed to work with all pulsed instruments including popular Rosemount and Honeywell models, PLCs, DCS recorders and all other.
  • Auto stepping
  • Accurate to ±0.1ºC (±0.2ºF)
  • Direct temperature
  • Input/Output
  • 8 Standard T/C types available
  • 8 RTD curves available
  • EZ-Dial™ Knob
  • EZ-Check™ Switch
  • Uses a standard 9V alkaline battery


4-20 mA Loop Calibrator

PIE 532 Loop Calibrator with Loop Diagnostic
PIE 532 Loop Calibrator with Loop Diagnostic
Need More information?
Download 532 Loop Calibrator with Loop Diagnostic Brochure PDF
Download PDF
>Visit PIE's website

  
Back to top - click here
The Practical Instrument Electronics' Model 532 is the best tool for calibration, test, and diagnosing process loops.  Make adjustments with the EZ-Set Dial or test limits with the Dual Action EZ-Span Switch.  Powerful ramping functions are only a button away on the Model 532. 

Save hours of troubleshooting time on problem loops with the 532’s unique Loop Diagnostic Mode. In Loop Diagnostic Mode, the loop current, voltage, impedance, AC voltage and mode of operation are all displayed simultaneously without the need of multiple DMM connections.  Included in the loop diagnostic features is the ability to measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges.

Loop diagnostics is available in every mode of operation as parameters are continuously updated in real time. The smart diagnostic tool even indicates the most likely cause of loop failure!
Features
  • Step & ramp functions
  • Read & source 0-24mA
  • Read 0.00 to +/- 30.00 VDC
  • Source 0.000 to 24.000 VDC
  • High resolution and full 5 digit display
  • True +/- 0.12% of reading accuracy
  • Loop diagnostics make dynamic loop readings under actual operating conditions
  • Measures ground current leakage, detects faulty wiring, wet conduit and corrosion bridges
  • Hands-free auto stop and auto ramp modes
  • HART® Compatible


Frequency Calibrator

PIE 541 Frequency Calibrator with Totalizer
PIE 541 Frequency Calibrator with Totalizer
Need More information?
Download 541 Frequency Calibrator with Totalizer Brochure PDF
Download PDF
>Visit PIE's website

  
Back to top - click here
The PIE Model 541 is the best tool for calibration, test, and diagnosing turbine meters, frequency counters, vibration systems, tachometers, vortex shedders, integrators, and any other Frequency devices in the shop, plant and/or field.

The Model 541 comes with an LED indicator showing gate time for easy trigger level adjustment.
Features
  • True ± 0.005% of range accuracy
  • Six Ranges 1 count per hour to 20.000Khz
  • Read 50mV to 120V peak
  • Reads signals from Flowmeter pickups, Velocity, and Motion Detectors
  • Calibrate Totalizer Input and Outputs from 1 to 99999 counts in 0.1 min. to 100.00 min.
  • LED Indicator for Gate Time
  • Source Sine and Square Waveforms, zero crossing or zero based

Download Product PDFs - An extensive list of Product Spec PDFs to download for your convenience. Can't open PDFs? Download the program from here!
Download Product PDFs - Click Here Get Adobe Reader - Click Here
.
Request More Product Info on a Product - Have a question or need advice on a product? Fill out our EASY online form for a quick reply from a Cameron Sales Rep! Request More Product Info on a Product - Have a question or need advice on a product? Fill out our EASY online form for a quick reply from a Cameron Sales Rep!
Click Here to Request More Info on a Product
.
Product Reference Guide
Crystal - click here for Crystal's website Digital Pressure Calibrators and Test Gauges.
>More Info >Visit Crystal's website
DHI - click here for DHI's website Pressure and Gas Flow Calibration Instruments.
>More Info >Visit DHI's website
Ebro - Click here for Ebro's website Handheld Measuring Instruments and Data Loggers.
>More Info >Visit Ebro's website
MPC - click here for MPC's website Visual Liquid Flow Indicators.
>More Info >Visit MPC's website
Orange Research - click here for Orange Research's website Differential Pressure & Liquid Flow Indicators.
>More Info >Visit Orange's website
Perma-Cal - click here for Perma-Cal's website Direct Drive Test & Process Gauges.
>More Info >Visit Perma-Cal's website
PIE - click here for PIE's website Process Calibrators: Loop, RTD & T/C Calibrators.
>More Info >Visit PIE's website
Ralston Instruments - click here for Ralston Instruments' website Portable Calibration Pumps, Hoses & Accessories.
>More Info >Visit Ralston's website
ThermaCal - click here for ThermaCal's website Dry Block Temperature Calibrators.
>More Info >Visit ThermaCal's website
Thommen - click here for Thommen's website Manometers & Barometers.
>More Info >Visit Thommen's website

Company Profile | Products | Used Equipment For Sale | Tradeshows | News | Tech Tips | Links | Contact Us | Request More Info | Download Product Spec PDFs | Home
©2008 Cameron Instruments. All Rights Reserved
Please read Cameron Instruments' Privacy Policy and Legal Notices.